Ultimate Top-Coat (UTC) Floor Coating by Colval™

Ultimate Top-Coat (UTC) Floor Coating by Colval™

UTC from The Concrete Experts. Simple application, extreme coating protection. One-part spray and walk away protective coating for polished concrete, warehouse floors and other high traffic areas. Easy to install, hard long-lived shine. Trust The Concrete Experts at Turning Point Supply for the best product advice and technical support, including UTC and other Coval systems.

Ask about Exclusive One-on-One Coval Product Training.

Just Spray and Walk Away Formula making it the easiest Nano Coating on the market today.

  • Covalent Bonding
  • Single Component
  • Stain Resistant Extreme Hardness
  • UV Stable
  • Spray Applied
  • Available in Gloss – Matte – Satin Finishes

Ultimate Top Coat reduces maintenance and is easy to clean, eliminating the need for guards, strippers, waxes, and harsh chemicals. Coval coatings contain less than 100 g/L VOCs and exceed SCAQMD Rule 1113 requirements for air quality; as well as contain no known carcinogens under Proposition 65, California’s Drinking Water and Toxic Enforcement Act of 1986. UTC is currently pending approval for Green Seal Certification (GS-11).

 

Product Request
Shipping Zip Code(Required)
MPN: UTC-1-1 SKU: UTC-Gloss-1G Categories: , , , Tags: , , Brand:

UTC from The Concrete Experts. Simple application, extreme coating protection. One-part sprays and walk away protective coating for polished concrete, warehouse floors, and other high traffic areas. Easy to install, hard long-lived shine. Trust The Concrete Experts at Turning Point Supply for the best product advice and technical support, including UTC and other Coval systems.

UltiGloss, Satin, Matte finishes. Designed for use over epoxy and highly polished and densified concrete. Recommended for use over polished concrete overlay materials such as Mapei and Rapid Set. Can be applied by hand on small areas such as concrete or epoxy countertops.

Coval Sealer - Ultimate Top Coat (UTC) Leaf Staining Test

(1 Month)

Coval Sealer - Ultimate Top Coat (UTC) Leaf Stain Test - One Month of Testing

UTC APPLICATION INSTRUCTIONS:

As with most final finishes, TOP-COAT is best sprayed on to achieve optimum finish and appearance. Use an Acetone Pump Sprayer with a red fan tip, or a full cone jet tip. Maintain consistent air pressure by pumping the sprayer regularly. With all methods of application, always mask off any adjacent surfaces to keep them free of drips or accidental coating.If applying outdoors, make certain the ambient temperature is between 45°F and 105° F, and RH is under 90%. Make certain that there is no chance of rain for a minimum of 5 hours after the estimated time of completion of the coating process. Also, make certain there will be no additional return of morning dew to make the surface damp again before it has had a chance to dry for at least 5 hours.

Ultimate Top Coat Application Types:

Pump Sprayer:
Satin & Matte finish: stir the contents thoroughly in the bottom of the container with a low-speed drill mixer. This is to re-suspend the matting agents that have settled to the bottom before pouring into a sprayer. Remove all particle filters in the sprayer to avoid clogging. Re-shake the pump sprayer every 10-15 minutes, to re-suspend the matting agents ensuring a consistent finish. Only use an acetone/alcohol-proof pump sprayer. Maintain an adequate PSI to create a consistent flow and finish. Maintain a 12-16” distance from the tip to the object. Apply 3-4 mils wet film thickness (WFT)and never allow puddling. It is always best to spray on a few mockups to get the feel of putting down this product before attempting an actual project. Be careful not to apply too thick (THIN TO WIN) or allow the product to puddle as this will cause too much surface tension and possible delamination.

UTC CLEAN-UP:

Clean tools and flush equipment with acetone at least twice immediately after application.IMPORTANT - once the coating is dry the tools will not clean up with acetone or any other solvent

Ultimate Top Coat reduces maintenance and is easy to clean, eliminating the need for guards, strippers, waxes, and harsh chemicals. Coval coatings contain less than 100 g/L VOCs and exceed SCAQMD Rule 1113 requirements for air quality; as well as contain no known carcinogens under Proposition 65, California’s Drinking Water and Toxic Enforcement Act of 1986. UTC is currently pending approval for Green Seal Certification (GS-11).

Testing Data:

 

Resin System

 

Component

 

Tack Free Time

Hardness D3363 Abrasion D4060  

Surface Prep

 

Adhesion

 

Coval Hybrid

 

1K

 

2-3 h

 

9H

 

<1 @ 7

Day cure

 

Clean Surface

 

Covalent Bond

 

Polyaspartic

 

2K

 

6-8 h

 

4H

 

61 @ 7

Day Cure

 

Profile required

 

Physical/charge

 

Epoxy

 

2K

 

24 h

 

6H

 

44 @ 7

Day Cure

 

Profile required

 

Physical/Charge

Polyurethane 2K 24 h 6H 2 @ 30

Day Cure

Profile required Physical


[embedyt] https://www.youtube.com/watch?v=k0VnZzbHm-o[/embedyt]

Product Enquiry

Download Now


Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

Download Now


Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab

Download Now


Loader Loading...
EAD Logo Taking too long?

Reload Reload document
| Open Open in new tab


%d bloggers like this: